01 Water Treatment: Accessories for a Spray Tray Deaerators (Industrial)

Accessories for a Spray Tray Deaerators (Industrial)

  1. Internal: Spray valves (stainless steel)
  2. Internal: Spray box (stainless steel)
  3. Internal: Trays (stainless steel)
  4. Internal: Vent condenser (stainless steel)
  5. Storage (for water storage after deaeration occurs) (carbon steel)
  6. Blowdown Tank (separate low pressure steam & condensate prior to deaerator) (if applicable)
  7. Chemical feed (oxygen scavenger)
  8. Optional: Chemical Feed Quill
  9. Optional: Control panel
  10. Flow switch (or transmitter)
  11. Insulation (external to vessel and piping)
  12. Level gauge (gauge glass) (or transmitter)
  13. Level switch (or transmitter)
  14. External piping
  15. Oxygen test kit (manual) or Oxygen Analyzer
  16. Pressure gauge (or transmitter)
  17. Pumps (inlet; outlet)
  18. Relief valve (sentinel type)
  19. Sample cooler (if applicable)
  20. Screen / Strainer
  21. Steam PRV (if applicable)
  22. Temperature gauge (or transmitter)
  23. Valves (inlet; outlet; overflow; overflow trap; steam control; bypass)
  24. Vacuum breaker (sentinel type)
  25. Vent valve
  26. Optional: Vent silencer (internal link)
  27. Optional: Control Panel (internal link)

Optional Accessory: Deaerator Head or Flash Condensing Deaerator Head: Spirax Sarco; ARI: Armaturen; Ayvaz (Istanbul); Caleffi: Discal (Italy); Forbes Marshall;
Valsteam: ADCA; and several manufacturers in India.

Note: There are “Test Kits” or “Analyzers” for Dissolved Oxygen; CHEMetrics and others manufacturer Dissolved Oxygen “Test Kits.”

Note: Bryan Steam manufacturers: “Hoppes” Overflow Trap; and Blowdown Tanks
Note: Gadren manufacturers: Lever Operated Float Valve that can be used as a Water Inlet Valve.
Note: Jordan Valve manufacturers: Float and Lever Operated Control Valve that can be used as a Water Inlet Valve.
Note: Keckley manufacturers: Float and lever valve that can be used as a Water Inlet Valve.
Note: Warren Controls manufacturers: Float Cage and Lever Water Inlet Valve, Overflow Trap, and Vacuum breaker

Note: A “Displacer Controller (Level Control)” can be an alternate method of controlling inlet flow or overflow.

Water Treatment: Exhaust Heads (internal link)

Link to Spray Tray Deaerator manufacturers (internal link)

Link to Tank: Condensate Pot, Condensate Chamber, Seal Pot, Seal Pot System, and Seal Water Pot: (internal link)

Navigate website: links are listed below: